Download here: http://gg.gg/o9i3h
It’s time to upgrade to business class. Trade in your MAC 1200, MAC 1600 or other ECG equipment for the MAC 2000 from GE Healthcare and profit from: Easy-to-read 7” color display; Full size A4/US letter thermal print-out; Full keyboard and easy-to-use interface; Paperless workflow for hospitals as well as practices. Description The GE Marquette MAC 1200 12-Channel EKG includes a patient cable, power cord, manual, clips, 100 electrodes, one pack of paper, and a new battery. Warranty: 90 Days - Parts and Labor. The MAC 1200 resting EKG system offers basic EKG solutions with practical features for clinics, office-based practices, and clinical trials.
*Ge Mac 1200 Ecg Machine Service Manual
*Ge Mac 1200 Ekg Machine Manual
*Ge Mac 1200 Ecg Machine Manual Pdf
*Ge Mac 1200 Ecg Machine Manual Instruction
The MAC 1200 is a compact 12-lead electrocardiograph designed for acquisition - with or without Interpretive analysis. Designed for use in clinics, physician offices and clinical trials, the MAC 1200 offers scaleable ECG solutions with practical features, while providing a high level of quality and convenience. All MAC 1200 ECG machines from GE Medical offer individually adjustable output formats for evaluation of the ECG and for archiving: One A4 page for the complete 12-channel resting ECG with all relevant curves, patient data, date, time and instrument settings Configurable parameters of the stress test reports.GE MAC 1200 Resting ECG SystemWhat is an ECG System?
Electrocardiography commonly referred to as either ECG or EKG is the recording of electrical activity from the heart over a period of time. The electrical activity is recorded with electrodes that are placed on the skin. Electrodes detect little electrical changes on the skin that arise from the heart muscle’s electrophysiology pattern of depolarizing and re-polarizing during each heartbeat. This process is called a cardiology test.
The electrodes are placed on the patient’s limbs and on the surface of the chest. On a typical 12-lead ECG the overall magnitude of the heart’s electrical potential is then measured from twelve different angles. Over a period of ten seconds, the overall magnitude and directions of the heart’s electrical depolarization is captured at each moment throughout the cardiac cycle. The graph depicted by the ECG system is called an electrocardiogram.Overview of the GE MAC 1200
The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).General Use of the GE MAC 1200
In the beginning of the recording, the automatic baseline adjustment algorithm verifies the incoming signal and adjusts the baseline position accordingly. During the recording, the anti-drift system (cubic spline) continuously checks the baseline position and returns it to the normal level if required. For manual mode, the anti-drift system (cubic spline) can be enabled and disabled from the setup menu. In the 12-lead and arrhythmia modes, it is always enabled.GE MAC 1200 Features
*This system can be configured to meet the needs of hospitals, clinics, and office-based practices
*Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
*Comprehensive solution for EKG requirements
*Waveform LCD display
*Interpretive EKG
*Full-size paper reports
*Portable with a built-in battery
*Measurements, interpretation, and memory available in any combination
*Simultaneous 12-lead ECG acquisition and analysis
*Compact, lightweight design with carrying handle
*Field upgradabilityGE MAC 1200 SpecificationsSignal Processing:
*Acquisition: 12 leads – simultaneously.
*Signal input: Type CF according to IEC.
*Digital sampling rate: 1000 samples/second/channel.
*Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV.
*Resolution: 5 uV.
*Frequency response:0.04 – 150 Hz.
*Common mode rejection:> 140 dB.
*Input impedance: > 100 M ohms.
*Leakage current: < 10uA.
*Pacemaker detection sensitivity: All leads, duration 0.1 – 2.5 ms, amplitude > 5 mV.Display:
*Type: LCD 320 x 240 pixel, backlit, Contrast adjustable.
*Displayed data: Selected lead group, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain, speed, name, ID, 3 ECG waveforms.Writer:
*Type: Thermal array print head.
*Resolution: Vertically 8 dots/mm horizontally 25um at 25 mm/s.
*Paper: 8.5 x 11 inch.
*Writer speed: 5, 25, 50 mm/s.
*Paper type: Z-fold.Keyboard:
*Type: Membrane keypad with tactile feedback / 46 keys.Special Functions:
*Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.
*Baseline adjustment: ECG presentation on the averaged baseline.
*Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.
*Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.
*Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.Power Supply:
*Ratings: 10 – 120 V (0.32A) / 220 – 240 V (0.16A).
*Frequency: 49 – 65 Hz.
*Battery type: NiCad, 18V, 1.4 Ah.
*Battery charge time: 4 hours.Physical Specs:
*Width: 14.5 in. (370 mm)
*Height: 3.7 in. (94 mm)
*Depth: 12.6 in. (320 mm)
*Weight: 12.4 lb. (5.6 kg) with graphics display and battery.
Have you used this product before? What features do you like? Comment below! One moment please...Not A Member?Sign UpGE Healthcare - Marquette MAC 1200by GE Healthcare
*Videos
*NewsDESCRIPTIONThe MAC 1200 Resting ECG System offers a comprehensive solution.
The MAC 1200 is a compact 12-lead electrocardiograph designed for acquisition - with or without analysis. The system can be configured as a basic electrocardiograph without analysis for facilities with minimal ECG requirements. The system can also be configured to incorporate the proven 12SLTM ECG analysis program. Adding the 12SL program creates an electrocardiograph with the industry leading interpretation program and measurements. If your facility only requires measurements, we offer a version with 12SL measurements only. FORUMSView All (34)Ask a New Question3Replies-Ahamayym3 months ago3 months agoTime and Date issueThe coin cell is at 3.25 VDC. The hardware test states that system memory and static memory both errored out. Is this a coin cell issue or the main board? Any assistance would be greatly appreciated.Reply-SKMR7 months ago7 months agonot printing in auto mode
i can not print in auto mode . what i could be the problem ?Reply1Reply-dPerk28289 months ago9 months agoFlashing LCD Upon StartupWhen I have the unit plugged in to a AC, the green standby light is on and when I press the ’on/ stdby’ button the green LED by ’start’ and yellow LED by ’battery low’ and ’stop’ will flash intermittently.I have tried a new main battery in the unit and that does not help.The power output from the power supply to the PCB is 25.8 DCV. Would not having the called for 26.5 DCV cause this issue or is that close enough to the called for output?ReplyDOCUMENTS / MANUALSView AllSERVICE COMPANIESView All Electrocardiograph (EKG / ECG) CompaniesFEATURES
*Waveform display
*Full-size paper reports
*Measurements, interpretation and memory available in any combination
*Simultaneous 12-lead ECG acquisition and analysis
*12SLTM Interpretation program
*Battery powered
*3-year warranty
*Easy to use
*Compact, lightweight design with carrying handle
*Field upgradabilityGe Mac 1200 Ecg Machine Service ManualSPECIFICATIONSGe Mac 1200 Ekg Machine ManualEKG/ECG TypeRestWeight12.3 lbs Ge Mac 1200 Ecg Machine Manual PdfGe Mac 1200 Ecg Machine Manual InstructionAdditional Specifications
Download here: http://gg.gg/o9i3h

https://diarynote.indered.space

コメント

最新の日記 一覧

<<  2025年7月  >>
293012345
6789101112
13141516171819
20212223242526
272829303112

お気に入り日記の更新

テーマ別日記一覧

まだテーマがありません

この日記について

日記内を検索